ADVIA CentraLink® Networking Solution - Technical

Technical specifications*
 

Configuration  
  Up to 15 user workstations
  Up to 32 instruments

 

Communication  
  Single LIS connection
  Downloads work orders to:
ADVIA WorkCell
ADVIA LabCell
  Manages work-order query from instruments
  Acts as a work-order buffer for automation systems
  Uses multiple communication protocols (ASTM, Spec 79, HL7)

 

Operating system  
  Windows® 2003

 

User interface  
  Standard Windows® navigation via drop-down menus and icons

 

Order entry  
  Simplified order entry for LIS back-up

 

Review and edit  
Options to: - Review all
- Review none
- Review by exception
Review can be customized for: - Range - definable by age, sex, species
- Delta checking - percentage & absolute basis
- QC violations
- Instrument flags
Dispositioning options: - Automatic or manual validation of results
- Rerun, omit or edit of results
- Manual result entry
- Keypad for manual differential result entry
- Ability to add comments to results
Display: - Option to configure the order of results display
- Option to view hematology cytograms from any workstation

 

Quality control  
  By method
  By lot or moving average
  By instrument
  By species
  Data display as:
- Results
- Levy-Jennings plots
  Westgard rules
(1-2s, 1-3s, 10-x, 2-2s, 4-1s, R-4s)
Add Comments during review
Support for use of comparators (<,>)
Omit data from statistical calculations

 

Search/Enquiry  
  By sample ID
  By physician name or ID
  By patient name or ID
  By instrument or instrument group
By test
By sample status

 

Multilanguage capabilities  
  Each workstation in your laboratory can be in the same or different languages
  Languages include: English, French, German, Italian, Dutch/Flemish, Portuguese, Norweigan

 

Security  
  Multiple standard and user-defined access levels
  Definable menu options for each access level
Validated for use with Trend™ OfficeScan™v 7.3
IT security configurations

 

Reporting  
  Customizable report formats:
- Report header
- Report footer
- Column headings
- Test display order

 

Data storage  
  Up to 30,000 samples per interfaced instrument
Up to 30,000 QC records per interfaced instrument

*ADVIA CentraLink Networking Solution version 12.0 required